50Hz Cummins NTA855-G1A 220kW/275kVA Diesel Generator Set

50Hz Cummins NTA855-G1A 220kW/275kVA  Diesel Generator Set

50Hz Cummins  220kW/275kVA  Diesel Generator Set

1.Technical Parameter

Parameter Item

Technical Data

Generator Set Model

Cummins NTA855-G1A Diesel Generator Set

Rated Frequency

50Hz

Prime Power (kW/kVA)

220kW / 275kVA

Standby Power (kW/kVA)

250kW / 313kVA

Full Load Fuel Consumption

61L/H

Rated Speed

1500RPM

Rated Voltage

400V/230V, Three-phase Four-wire

Power Factor

0.8 Lagging

Engine Brand

Genuine Chongqing Cummins

Engine Model

NTA855-G1A

Engine Structure

6-cylinder, 4-stroke, In-line, Water-cooled, Turbocharged & Air-air Intercooled

Bore * Stroke

140mm * 152mm

Displacement

14L

Engine Rated Power

261kW @ 1500RPM

Compression Ratio

14.5:1

Fuel System

Cummins Original PT Fuel System + Electronic Governor

Speed Regulation Accuracy

≤±1%

Total Lube Oil System Capacity

38.6L

Max Allowable Oil Temperature

121℃

Cooling System

Self-circulating Water Cooling Radiator

Alternator Excitation Type

Brushless, Self-excited, Full Copper Winding

Insulation Grade

H Grade

Protection Grade

IP23

Voltage Regulation Mode

Automatic AVR Constant Voltage Regulation

Starting Mode

24V DC Electric Start

Working Temperature Range

-20℃ ~ +45℃

Average Trouble-free Operation Hours

≥2600 Hours

Overhaul Service Life

≥8500 Hours

Emission Standard

China Stage II / Euro 2 Compliant

2. Core Product Features

The Cummins NTA855-G1A 220kW/275kVA diesel generator set is a classic heavy-duty industrial power generation unit equipped with genuine Chongqing Cummins 14L super large-displacement engine. Belonging to the mature and stable NTA855 series platform that has been verified by decades of market applications, this model adopts exclusive Cummins PT fuel supply system and turbocharged intercooled technology. It stands out in the medium and high-power genset market for its ultra-strong power stability, excellent harsh environment adaptability and ultra-long service life, and is widely recognized as a reliable 275kVA large-displacement heavy-duty Cummins generator for industrial continuous power supply and engineering emergency standby power scenarios.

2.1 14L Super Large Displacement Turbocharged Intercooled Design, Abundant Power Reserve

Powered by genuine Chongqing Cummins NTA855-G1A inline six-cylinder four-stroke water-cooled engine, the unit adopts professional turbocharged and air-air intercooled dual optimization technology. The 14L super large displacement and 140mm×152mm oversized bore-stroke structure bring far more sufficient power reserve than conventional 9L displacement generators of the same power level. It fundamentally solves the common problems of power attenuation, insufficient peak power and overload shutdown of medium-displacement units during long-term full-load and high-temperature operation. The factory-calibrated prime power reaches 220kW/275kVA, and the emergency standby power is up to 250kW/313kVA, with a super-high overload margin. It can easily cope with instantaneous startup surge of large mechanical equipment and long-term variable load alternating operation. Matched with full-copper brushless alternator and high-precision AVR automatic voltage regulation system, the unit maintains ultra-low voltage and frequency fluctuation, stably outputting standard 50Hz industrial power supply, fully meeting the high-stability power demand of heavy industrial equipment and large engineering machinery.

2.2 Original PT Fuel System + Electronic Speed Regulation, Stable Combustion & Reliable Fuel Consumption

This 220kW Chongqing Cummins heavy-duty diesel generator is equipped with Cummins patented original PT fuel supply system, matched with high-precision electronic governor. Different from traditional mechanical fuel supply structures, the PT system features precise fuel injection metering, uniform diesel atomization and sufficient combustion efficiency, effectively improving power generation efficiency while controlling fuel consumption stably. The full-load fuel consumption is fixed at 61L/H, with almost no fluctuation after long-cycle continuous operation, which is convenient for enterprises to carry out daily power generation cost accounting and long-term operation budget management. The electronic speed regulation accuracy is controlled within ±1%, with sensitive dynamic load response, no frequency drift or voltage surge during frequent load switching, and always maintains stable operating state under complex variable load working conditions.

2.3 Reinforced Integral Cast Iron Structure, Ultra-high Durability & Low Failure Rate

Aiming at long-cycle high-load operation and harsh outdoor working conditions, the NTA855-G1A engine adopts integral thickened cast iron cylinder block and high-strength forged steel crankshaft structure, with extremely high structural rigidity and strong vibration and impact resistance. The optimized overall sealing process completely eliminates the oil and water leakage faults that are easy to occur in traditional high-power generators. Equipped with wear-resistant cylinder wall and high-temperature resistant piston accessories, the unit adapts to long-term high-load and high-temperature continuous operation. The average trouble-free operation hours reach 2600 hours, and the overhaul service life is extended to more than 8500 hours, far exceeding most mainstream gensets of the same power level. With few vulnerable parts and low daily maintenance difficulty, it can realize long-term unattended operation, greatly reducing later operation and maintenance costs for users.

2.4 Brushless Maintenance-free Alternator + Complete Intelligent Safety Protection

The alternator part adopts mature brushless self-excited excitation design, eliminating carbon brushes, slip rings and other easily worn parts of traditional brushed generators, fundamentally reducing mechanical failure points and daily maintenance workload. The H-grade ultra-high temperature resistant insulation material can resist long-term high-temperature aging, moisture erosion and electrical breakdown, ensuring stable power generation performance in high-heat, humid and dusty environments. The IP23 dust-proof and splash-proof protection grade can effectively isolate construction dust, debris invasion and light rain splash, supporting indoor generator room fixed installation and outdoor awning protection placement. Meanwhile, the unit is equipped with complete intelligent protection functions including low oil pressure alarm shutdown, high water temperature overheat protection, overload protection, overvoltage and undervoltage protection and overspeed automatic shutdown, which can quickly respond to abnormal working conditions to protect equipment operation safety and avoid operational accidents.

3. Main Application Scenarios

Relying on 14L large-displacement strong power performance, decades of mature technical verification and excellent full-load stability, the Cummins NTA855-G1A 220kW/275kVA diesel generator set is widely used in heavy industrial manufacturing, open-pit mining operations, large-scale municipal infrastructure, port terminal engineering, industrial park standby power and municipal emergency power guarantee fields. It is the most trustworthy choice for 275kVA industrial long-term continuous power generation and 313kVA engineering emergency standby power supply.

3.1 Heavy Industrial Manufacturing & Processing Bases

It is suitable for large machinery processing, metallurgical production workshops, chemical industrial parks, building materials processing, non-ferrous metal smelting and large food deep processing enterprises. Heavy industrial production has extremely strict requirements for power supply continuity and load stability. Sudden grid power failure, seasonal power rationing and routine power grid maintenance will directly cause full production line shutdown and huge economic losses. This large-displacement heavy-duty generator has strong instantaneous overload resistance and fast load switching response speed, which can quickly take over power supply to ensure the normal operation of heavy production equipment, workshop ventilation and water supply systems and intelligent monitoring equipment, effectively guaranteeing uninterrupted industrial production.

3.2 Mining & Remote Off-grid Field Operation Sites

For open-pit mining, underground mining auxiliary power supply, mountain field exploration, remote highway and railway construction and other scenarios without complete municipal power grid coverage, this Cummins NTA855-G1A off-grid diesel generator serves as the core main power supply equipment. Its turbocharged intercooled heat dissipation structure adapts to dusty, high-temperature and variable-load harsh mining working conditions, and the original PT fuel system ensures stable power output under long-term continuous operation. The 14L large-displacement power core supports 24-hour uninterrupted high-load power generation, fully meeting the power demand of mining machinery, field office communication equipment and staff living supporting facilities.

3.3 Large-scale Municipal Infrastructure & Port Projects

It is the preferred power guarantee equipment for long-cycle key projects such as municipal road and bridge engineering, large-scale water conservancy and hydropower construction, tunnel engineering, urban comprehensive renovation and port terminal operation. Large infrastructure projects have long construction cycles and complex outdoor working environments, and rely heavily on stable mobile power supply. The unit has excellent environmental adaptability and anti-interference performance, can resist outdoor temperature changes, wind and dust erosion, and provides continuous and stable power support for large engineering machinery and construction auxiliary equipment, ensuring the smooth progress of key municipal projects.

3.4 Large Industrial Parks & Commercial Complex Clusters

Suitable for comprehensive industrial parks, super-large shopping mall clusters, high-rise office buildings and five-star hotel groups with large power consumption and high power supply reliability requirements. These scenarios have dense electrical equipment and large peak power consumption. In summer high-temperature power tension periods, sudden grid failures and routine power maintenance, the unit can automatically start and switch power supply, ensuring the normal operation of fire control linkage systems, emergency elevators, public lighting and central air conditioning systems, maintaining stable commercial operation order and industrial park production efficiency.

3.5 Municipal Public Facilities & Emergency Rescue Fields

It can be used as emergency backup power for regional central hospitals, fire rescue brigades, municipal emergency command centers, environmental monitoring stations and traffic management centers. In sudden power outage emergencies, the unit can respond rapidly with stable high-power output, providing reliable power guarantee for medical rescue equipment, fire alarm linkage systems, emergency disposal equipment and precision monitoring instruments, effectively improving regional public service capacity and emergency rescue efficiency.

4. Core Product Purpose

Positioned as a mature durable Cummins 275kVA large-displacement diesel generator, the NTA855-G1A model focuses on solving long-cycle high-load continuous power supply and high-reliability emergency power guarantee demands in harsh industrial and complex engineering scenarios, covering industrial emergency standby power, off-grid main power supply, power grid peak regulation and key public facility power backup.

Firstly, it provides high-reliability emergency backup power for heavy industrial enterprises. Aiming at large heavy industrial parks and high-load manufacturing bases, it responds to sudden grid outages, seasonal power rationing and routine power cut maintenance, avoiding large-scale production shutdown and equipment stagnation caused by power interruption, and building a solid power safety barrier for enterprise continuous production.

Secondly, it acts as long-term stable prime power for off-grid mining and field engineering. For remote mining areas, field construction sites and weak grid areas with unstable voltage, the unit can operate continuously for 24 hours as the main power generation equipment, stably outputting 220kW rated power to meet the long-term production, processing and living power demand of field operation teams.

Thirdly, it undertakes power grid peak shaving and auxiliary power supply for high-consumption scenarios. In summer high-temperature peak power consumption periods with tense regional power supply, the generator set can be started for auxiliary power supply to make up for municipal power grid capacity shortage, relieve equipment overload pressure, and avoid project stagnation and economic losses caused by power shortage.

Finally, it provides high-stability power guarantee for key professional equipment. Relying on Cummins original PT fuel system and AVR constant voltage technology, the unit has extremely low power supply fluctuation, which can supply high-quality pure power for medical rescue devices, fire control systems, environmental monitoring instruments and industrial precision processing equipment, avoiding equipment failure, data loss and safety accidents caused by unstable power supply.

5. Common FAQ

Q1: What is the practical usage difference between prime power and standby power of Cummins NTA855-G1A generator?

The 220kW/275kVA prime power is the long-term continuous operating power officially calibrated by Cummins, supporting 24-hour uninterrupted stable operation all year round, which is suitable for daily off-grid main power supply and long-term industrial high-load standby scenarios. The 250kW/313kVA standby power is short-term emergency peak power, only allowing 1-hour overload operation within 12 hours, and long-term operation under standby load is strictly prohibited in actual use. According to years of on-site engineering operation experience, controlling the long-term operating load within 80% of prime power can effectively reduce engine mechanical wear, stabilize fuel consumption and maximize the overall service life of the NTA855-G1A 275kVA heavy-duty diesel generator set.

Q2: What core advantages does NTA855-G1A 14L large-displacement unit have over conventional medium-displacement gensets?

The biggest core advantage of the NTA855-G1A unit is its 14L super large-displacement and mature Cummins PT fuel system, which is completely different from conventional 8.9L and 9.5L medium-displacement generators. It has more abundant power reserve, stronger anti-power attenuation ability under full-load high-temperature operation, and more stable load response. The exclusive PT fuel supply technology ensures more sufficient combustion and more stable fuel consumption in long-cycle operation, with lower failure rate and better harsh environment adaptability. In addition, the integral cast iron body structure has higher durability, longer trouble-free operation time and overhaul cycle, making it more suitable for long-term uninterrupted power generation in mining, chemical industry and other high-load harsh scenarios.

Q3: What installation and daily maintenance precautions are required for IP23 NTA855-G1A heavy-duty generator?

This classic large-displacement heavy-duty unit has IP23 dust-proof and splash-proof protection and H-grade high-temperature insulation performance, adapting to indoor generator room fixed installation and outdoor awning protective placement, and can cope with harsh working conditions such as construction site dust and seasonal high-temperature operation. During installation, sufficient heat dissipation and maintenance space must be reserved around the unit to avoid high-temperature alarm and shutdown caused by poor heat dissipation of the 14L large-displacement engine. In daily maintenance, regularly replace lubricating oil and three filters, focus on checking the working state of the original PT fuel system and electronic governor, and keep the fuel pipeline unobstructed. Avoid long-term full-load overload operation in daily use to ensure long-term stable and efficient operation of the unit.

 


Quick Inquiry