Good Reputation Supplier 10kv 400v Three Phase Oil Immersed Transformers

Good Reputation Supplier 10kv 400v Three Phase Oil Immersed Transformers
Main Parameters
Parameter | Specification |
Rated power | 1,000 kVA reference design; 100–2,500 kVA available |
Type | Three-phase, two-winding, oil-immersed distribution transformer |
Frequency | 50 Hz standard; 60 Hz as a separate design |
Primary voltage | 10,000 V nominal, Um 12 kV |
Taps | ±2 × 2.5%, off-circuit, five positions: 10,500 / 10,250 / 10,000 / 9,750 / 9,500 V |
Secondary voltage | 400 V line-to-line, 230 V line-to-neutral |
Vector group | Dyn11 standard; Yyn0 or Dd0 on request |
Rated current | ≈ 57.7 A on the HV side, ≈ 1,443 A on the LV side |
Impedance | 4.5% at 75 °C; 4.0–6.0% according to the project's fault level |
No-load loss | ≈ 1,200 W |
Load loss | ≈ 9,800 W at 75 °C, full load |
Full-load efficiency | ≈ 98.9% |
Temperature rise | 65 K average winding, 60 K top oil; 55 K version for high ambient |
Cooling | ONAN; ONAF available on larger ratings |
Insulating fluid | Mineral oil to IEC 60296, ≈ 620 kg; ester fluid on request |
Core | Grain-oriented silicon steel, three-limb, mitred step-lap joints |
Windings | Copper HV layer winding, copper LV foil; aluminium on request |
Tank | Welded steel, corrugated wall, hermetically sealed; conservator version available |
Insulation level | 75 kV lightning impulse, 28 kV power-frequency withstand at Um 12 kV |
HV termination | Cable box or porcelain bushings, 12 kV class |
LV termination | Cable box or busbar chamber rated for the ≈ 1,440 A secondary current |
Tap changer | Off-circuit, five positions, lockable, external handle |
Fittings | Pressure relief device, thermometer pocket, drain and filter valves, lifting lugs, jacking pads, earthing terminals |
Sound level | ≤ 55 dB(A) at 1 m |
Mass | ≈ 2,600 kg complete; oil ≈ 620 kg |
Standards | IEC 60076-1, -2, -3, -5; IEC 60296; GB 1094 / GB/T 6451 equivalent; CE marking on request |
Tests | Routine: winding resistance, ratio and vector group, no-load loss and current, load loss and impedance, applied and induced voltage, insulation resistance, oil breakdown, tap changer operation. Type: impulse, temperature rise, sound level |
Loss values are design figures. The routine test report that goes out with each unit carries the measured no-load loss, load loss, impedance and ratio for that serial number — and the first thing a serious buyer does is check that the numbers on the report match the ones on the nameplate and on the offer.
Product Description
Ten kilovolts to 400 V is the standard distribution step for plants, buildings and utility LV networks across most of Asia, Europe, Africa and the Middle East. At 1,000 kVA the primary draws about 58 A, so the HV winding is a copper layer winding with graded insulation built to a 75 kV impulse level, which is what the 12 kV class requires. The secondary carries about 1,443 A, which is busbar territory: copper foil winding, a cable box with real gland plates or a busbar chamber, and terminals sized for the current rather than a nominal figure.
The transformer itself is conventional engineering done properly: a four-limb or three-limb grain-oriented core with mitred step-lap joints, no-load loss near 1,200 W, a 4.5% impedance that holds secondary fault current around 32 kA, and five off-circuit taps covering the 9,500–10,500 V band. None of that is exotic. What separates suppliers is whether the copper is actually copper, whether the core is actually grain-oriented, whether the losses on the report are measured or copied, and whether the tank still holds vacuum after a sea voyage.
Mechanically, the tank is corrugated and sealed under vacuum, with expansion taken by the wall, so there is no conservator or breather to service. Where a utility's practice expects a conservator, that version is available, and the choice changes the overall height and the shipping volume — a detail worth settling before the plinth is built rather than after.
Reputation in this trade is built on repeatable details: the same copper weight batch after batch, the same loss level from the first unit to the twentieth, drawings issued before production rather than after, and a serial-numbered test report that a third-party inspector can verify. Buyers who have been burned once usually start asking for exactly those items — and a supplier who has them answers without hesitation.
Core Uses
The unit takes 10 kV down to a 400 V three-phase supply for a plant or a building section. Five uses account for most orders on this ratio.
• Plant incoming supply. One 10 kV connection stepped down to 400 V for the whole low-voltage distribution.
• Motor and process load supply. Pumps, compressors, fans, conveyors and machine lines fed at 400 V.
• Commercial and mixed-use buildings. HVAC, lifts, lighting and tenant distribution from a single transformer.
• Utility LV distribution points. A transformer at the end of a 10 kV feeder serving a residential or mixed cluster.
• Replacement and capacity upgrades. Old units swapped for a low-loss build on the same foundation and cable entries.
Application Scenarios
This ratio fits loads from a few hundred kVA to a couple of MVA where the supply is 10 kV and the distribution is 400 V. The table maps the situations that generate most of our enquiries.
Scenario | Typical load | Why this unit fits |
Industrial plants and factories | Motor loads, process lines, plant lighting | 10 kV is the common incoming voltage; 400 V matches local motors and panels |
Commercial and residential buildings | HVAC, lifts, tenant and dwelling distribution | Compact sealed unit for a basement or plinth; Dyn11 gives 230 V for single-phase circuits |
Water treatment and pumping | Pump motors, blowers, controls | Sealed tank and 65 K rise suit unattended stations in hot climates |
Utility LV distribution | Residential cluster, shops, street lighting | Standard rating that utilities hold as spares; consistent documentation for asset registers |
EPC and export projects | Site distribution, often repeated across a project | Per-unit test reports, witnessed FAT and export packing that survives sea freight |
Replacement programmes | Ageing units with rising loss and oil leaks | Same footprint and cable entries, modern loss level, no downstream changes |
Where the incoming supply is 20 kV or 35 kV, this is not the right unit whatever the taps say; the insulation class and ratio are both wrong. And where the load is genuinely single-phase, a three-phase transformer is an expensive way to serve it — a single-phase pole mount usually costs less and needs less space.
Product Features
At this rating, features are mostly about verifiability. These are the points a buyer can check before the order, not after.
• Copper windings, stated in writing. Winding material named in the offer and the nameplate, so it can be checked on arrival instead of assumed.
• Measured losses per unit. Around 1,200 W no-load and 9,800 W load loss, with the measured figures on a serial-numbered test report.
• Sealed corrugated tank, vacuum filled. No conservator, no breather, no oil gauge to misread; the conservator version available where utility practice requires it.
• 10 kV class insulation. 75 kV impulse level, graded HV winding, and a 28 kV power-frequency withstand with proper bushing creepage.
• LV termination sized for 1,443 A. Cable box with gland plates or busbar chamber, quoted against the real current.
• Impedance agreed with the fault level. 4.0–6.0% selected per project so breakers and protection settings line up at the first review.
• Documents issued before production. Approved outline and connection drawings, then a test report, oil certificate and packing list per unit.
• Witnessed testing on request. Routine tests per IEC 60076-1 with the buyer's inspector present, and third-party inspection where the project requires it.
Questions Buyers Ask
Question | Answer |
How do I verify a supplier's reputation? | Ask for three things: past test reports with matching serial numbers, contactable references on comparable ratings, and a drawing issue process. A supplier who cannot produce the first item is not established, whatever the website says. |
What should the test report contain? | Winding resistance, ratio and vector group, no-load loss and current, load loss and impedance, applied and induced voltage, insulation resistance and oil breakdown — all tied to the serial number on the nameplate. |
Is 4.5% impedance enough for a 1 MVA unit? | It holds secondary fault current near 32 kA, which ordinary 400 V switchgear can break. If the panel is rated lower, the impedance or the switchgear has to change, and that is agreed before the order rather than after. |
Can it run at high ambient or altitude? | Yes, with a different temperature-rise class or a derating. Above 1,000 m cooling performance drops, and a 55 K rise design is usually cheaper than buying the next rating up. |
Can two units be paralleled? | Same vector group, ratio, tap position and impedance, with load sharing designed in. A 4.5% unit in parallel with a 6% unit is a common and costly mistake. |
What is needed for a quotation? | Rating, voltages, tap range, vector group, impedance or fault level, termination types, cooling, ambient and altitude, quantity and destination port. |
Send the single-line diagram and the fault level with the enquiry, and ask for the documentation package in the same email as the price. A supplier who answers both in one reply is the one worth a second order — and in this trade, the second order is what reputation actually means.