60Hz SDEC 4Z2.3-G12 16kW/20kVA Diesel Generator Set

60Hz SDEC 4Z2.3-G12 16kW/20kVA  Diesel Generator Set

60Hz SDEC  16kW/20kVA  Diesel Generator Set

1. Technical Parameter

Parameter Item

Specific Data

Unit Model

SDEC 4Z2.3-G12 Diesel Generator Set

Rated Frequency

60Hz

Prime Power (kW/kVA)

16kW/20kVA

Standby Power (kW/kVA)

17.6kW/22kVA

Full Load Fuel Consumption (L/H)

4.68L/H

Rated Rotating Speed

1800RPM

Rated Voltage

400/230V (3 Phase 4 Wire)

Power Factor

0.8 Lagging

Engine Brand

SDEC (Shanghai Diesel Engine)

Engine Model

4Z2.3-G12

Engine Displacement

2.3L

Cylinder Configuration

4-Cylinder, In-line, Direct Injection

Combustion Mode

Direct Injection Combustion

Alternator Excitation Type

Brushless, Self-excited

Insulation Class

H Grade

Protection Grade

IP23

Voltage Regulation Mode

Automatic Voltage Regulation (AVR)

Steady-state Voltage Adjustment Rate

≤±0.5%

Ambient Operating Temperature

-25℃ ~ 50℃

Maximum Applicable Altitude

≤1000m

2. Product Features

This SDEC 4Z2.3-G12 16kW 60Hz diesel generator set is a high-efficiency and low-consumption small-power generating equipment independently developed by Shanghai Diesel Engine, which is widely recognized in the industry as a reliable 60Hz small diesel generator set. It is specially optimized for overseas power standards and small and medium power demand scenarios, with outstanding comprehensive performance and ultra-high cost performance, becoming the preferred equipment for industrial standby power supply and outdoor emergency power generation.

In terms of power performance, the unit is equipped with the original SDEC 4Z2.3-G12 dedicated generator engine, adopting in-line four-cylinder direct injection technology and supercharging intercooling design. The prime power reaches 16kW/20kVA, and the standby power can stably burst 17.6kW/22kVA, which can fully cope with instantaneous load surge and long-term continuous power supply. The 1800RPM constant-speed operation mode matches the 60Hz power frequency standard perfectly, ensuring stable frequency and voltage output without fluctuation, effectively avoiding equipment damage caused by unstable power supply, and meeting the strict power supply requirements of precision electrical equipment.

In terms of energy saving and economy, the unit has excellent fuel control capability. The full-load fuel consumption is only 4.68L per hour, which is far lower than most peer products of the same power. As a low fuel consumption diesel generator, it can greatly reduce the operating cost of long-term power generation. Meanwhile, the original engine has low wear and low oil consumption, with stable performance after thousands of hours of operation, reducing the frequency of maintenance and parts replacement, and realizing long-term low-cost operation.

In terms of safety and durability, the supporting brushless self-excited alternator adopts H-grade high-temperature resistant insulation material, which has strong anti-aging and anti-breakdown ability, and can maintain stable operation in high-temperature and humid environments. The IP23 professional protection grade can effectively block dust, rainwater and small particle impurities, preventing internal circuit and mechanical failure. Different from brushed alternators, the brushless design avoids carbon brush wear and spark failure, reduces failure points, and greatly improves the continuous operation stability of diesel generator set.

In terms of operation and maintenance, the unit is equipped with a full automatic voltage regulation system, which can realize automatic voltage stabilization and frequency modulation without manual frequent adjustment. The integrated body structure is compact in size, light in weight and easy to move and install. The whole machine has a simple circuit and mechanical structure, with few vulnerable parts, convenient daily inspection and maintenance, and low technical threshold for operators, which is very suitable for unattended long-term standby operation.

3. Application Scenarios

Relying on stable 60Hz power output, low energy consumption and high safety performance, the SDEC 4Z2.3-G12 16kW diesel generator set covers multiple mainstream scenarios such as commercial standby, industrial emergency, outdoor construction and overseas power supply, and is a versatile 16kW industrial diesel generator for small and medium power scenarios.

3.1 Commercial Building & Civil Facilities Standby Power

It is applicable to small shopping malls, community property offices, office buildings, hotels and catering venues that adopt 60Hz power standard. When the municipal power is cut off suddenly, the unit can start quickly to supply power for lighting, monitoring, office equipment and fire emergency facilities, avoiding economic losses and safety hazards caused by power outage, and ensuring the normal operation of commercial and civil facilities.

3.2 Industrial Small Workshop Production Power

For small processing workshops, mechanical processing factories and electronic assembly workshops with low power demand, this generator set can be used as both conventional auxiliary power and emergency standby power. Its stable voltage and frequency output can protect precision processing equipment and testing instruments from power fluctuation interference, and ensure the consistency of product processing quality, which is an ideal factory emergency backup generator.

3.3 Outdoor Engineering & Field Operation Power

It is perfectly suitable for outdoor scenarios without municipal power supply, such as road construction, municipal engineering maintenance, field exploration and construction site temporary power use. The compact and movable design adapts to complex field working conditions, and the low fuel consumption advantage can effectively control the power consumption cost of long-term field operation, solving the power supply problem of off-grid field operation.

3.4 Overseas Project & Foreign Trade Power Supply

Targeting at overseas markets with 60Hz power standard such as Southeast Asia, Africa and the Middle East, the unit’s 60Hz fixed frequency design is fully compatible with local power grid and electrical equipment standards. It is widely used in overseas small engineering projects, residential area supporting power supply and overseas warehouse standby power, and is a hot-selling 60Hz export diesel generator set in the foreign trade industry.

3.5 Communication & Monitoring Emergency Power

It can be used as standby power for communication base stations, outdoor monitoring systems, smart equipment and weak current systems. The stable and uninterrupted power output ensures the continuous operation of communication and monitoring equipment, avoiding signal interruption and monitoring blind spots caused by power failure, and improving the safety and stability of intelligent equipment operation.

4. Core Purpose

The core positioning of the SDEC 4Z2.3-G12 16kW/20kVA 60Hz diesel generator set is to provide stable and efficient emergency standby power and off-grid independent power supply for small and medium power demand scenarios, focusing on solving the power supply pain points such as sudden power outage, unstable municipal power and no grid power coverage.

Its first core purpose is emergency power backup. In commercial, industrial and public facility scenarios, it serves as an indispensable backup power equipment. Once the municipal power fails, it can quickly switch to power supply mode, ensure the uninterrupted operation of key equipment, reduce power outage losses, and meet the emergency power guarantee needs of various industries. As a professionalstandby diesel generator set, its 10% standby power margin can cope with various instantaneous load changes.

The second core purpose is off-grid independent power generation. For field construction, remote areas, overseas unpowered areas and other off-grid scenarios, it can be used as the main power supply equipment to provide long-term stable 60Hz standard power output for construction equipment, living facilities and production equipment, completely solving the power shortage problem of off-grid scenarios.

The third core purpose is stable power regulation and power quality optimization. Equipped with AVR automatic voltage regulation system and brushless excitation technology, the unit can effectively suppress voltage and frequency fluctuation, improve power supply quality, protect precision electrical equipment from damage, and is especially suitable for scenarios with high requirements for power supply stability such as electronic processing and intelligent monitoring.

In addition, the unit also undertakes the auxiliary power supply task of daily peak shaving. In areas with tight municipal power supply and peak power limitation, it can be started in peak power consumption period to share part of the power load, reduce enterprise power consumption pressure, and achieve the effect of peak shaving and power saving.

5. FAQ (Common Questions)

Q1: What is the difference between prime power and standby power of this 4Z2.3-G12 generator set?

Prime power (16kW/20kVA) refers to the rated continuous power, which supports long-term uninterrupted operation and can bear 100% load for a long time, suitable for daily off-grid main power supply. Standby power (17.6kW/22kVA) is the emergency peak power, which is 10% higher than the prime power. It is only used for short-term emergency power supply when the municipal power is cut off, and cannot operate under full load for a long time. Users can select the power mode according to daily use scenarios to avoid overload operation failure.

Q2: Is this SDEC diesel generator set suitable for 60Hz overseas export scenarios?

Absolutely applicable. This unit is professionally calibrated for 60Hz frequency, with a rated speed of 1800RPM, fully matching the power standard of most overseas countries and regions such as Southeast Asia, Africa and Latin America. The IP23 protection grade and H-grade insulation design adapt to complex overseas climatic environments such as high temperature and humidity. Meanwhile, the original SDEC engine has complete after-sales service system overseas, which is the preferred model for 60Hz generator set export, with high market recognition and stable performance.

Q3: How to reduce the fuel consumption of the 4Z2.3-G12 generator set during daily use?

The full-load fuel consumption of the unit is 4.68L/H, and the fuel consumption can be effectively optimized through standardized operation. First, avoid long-term full-load overload operation, and match the load reasonably according to the actual power demand; second, conduct regular maintenance including replacing diesel filter, oil filter and air filter to ensure sufficient combustion; third, avoid frequent start and stop of the unit, and keep continuous and stable operation for medium and long-term power supply; finally, use qualified standard diesel oil to reduce combustion loss and carbon deposition, which can significantly reduce daily operating fuel consumption.

 


Quick Inquiry