60Hz YUCHAI YC16VTD2700-D32 1700kW/2125kVA Diesel Generator Set

60Hz YUCHAI 1700kW/2125kVA Diesel Generator Set
1.Technical Parameter
Parameter Item | Technical Data |
Genset Model | YC16VTD2700-D32 |
Brand | YUCHAI Industrial Power |
Rated Frequency | 60Hz |
Prime Power (kW/kVA) | 1700kW / 2125kVA |
Standby Power (kW/kVA) | 1800kW / 2250kVA |
100% Full Load Fuel Consumption | 444.3 L/H |
Rated Voltage | 400/230V, Three-phase four-wire |
Rated Power Factor | 0.8 Lagging |
Rated Speed | 1800rpm (60Hz dedicated calibration) |
Engine Model | YUCHAI YC16VTD2700-D32 |
Engine Configuration | 16-cylinder V-type, four-stroke, turbocharged & intercooled, water-cooled |
Fuel Injection System | Electronic high-pressure common rail intelligent injection |
Starting System | 24V DC electric automatic starting |
Cooling Method | Closed circulating forced water cooling |
Alternator Excitation Type | Brushless, self-excited |
Insulation Class | H Class |
Protection Grade | IP23 |
Voltage Regulation | Automatic AVR electronic constant voltage control |
Operating Temperature Range | -20℃ ~ +45℃ |
Max Adaptable Altitude | ≤1000m (no power attenuation) |
Output Waveform | Pure sine wave AC output |
2. Product Features
The YUCHAI YC16VTD2700-D32 60Hz diesel generator set is a heavy-duty ultra-high-power industrial genset developed for large-scale industrial power supply and high-standard overseas engineering projects. As a mainstream 1700kW prime power diesel generator and 2250kVA standby power generation unit in the global industrial power market, it adopts Yuchai’s mature 16-cylinder V-type heavy-duty power platform, featuring sufficient power reserve, strong load impact resistance and stable continuous operation performance. It solves the long-term high-load power supply pain points of large industrial parks and cross-border engineering projects, and is recognized as a reliable high-power 60Hz power generation solution for heavy industrial scenarios.
In terms of power performance, this 2125kVA industrial diesel generator set is equipped with a customized YC16VTD2700-D32 heavy-duty diesel engine. The rated prime power reaches 1700kW, and the emergency standby power is up to 1800kW, with ultra-high power redundancy. The optimized 16V cylinder arrangement and turbocharged intercooled structure ensure sufficient air intake and efficient fuel combustion, bringing stronger transient loading capacity and stable power output. It can withstand instantaneous peak load surges of large-scale mechanical equipment and support 24-hour uninterrupted full-load operation, fully meeting the continuous power demand of heavy industrial production. The standard 60Hz frequency and 1800rpm rated speed are highly compatible with the power supply standards of North America, Southeast Asia and other overseas regions, eliminating frequency mismatch faults of supporting electrical equipment.
In terms of operational economy, the unit adopts advanced electronic high-pressure common rail fuel injection technology, which can precisely control fuel injection pressure, injection timing and atomization effect, realizing full fuel combustion and low energy loss. The full-load fuel consumption is stably controlled at 444.3L/H. Compared with peer 1700kW high-power diesel generator sets, it achieves a perfect balance between ultra-high power output and moderate fuel consumption, effectively reducing long-term operating fuel costs for enterprises. The optimized engine calibration and matching design also reduce idle fuel consumption and exhaust emissions, meeting international industrial environmental protection operation standards.
For power generation stability and maintenance convenience, the matched brushless self-excited alternator abandons the traditional carbon brush structure, completely avoiding carbon brush wear, spark interference and frequent replacement maintenance problems. Equipped with a high-precision AVR automatic voltage regulator, the unit can dynamically adjust output voltage in real time according to load changes, ensuring stable voltage and frequency output. The pure sine wave power supply effectively protects precision industrial control instruments, automated production lines and high-value electrical equipment from damage caused by voltage fluctuation and frequency drift. Adopting H-grade ultra-high temperature resistant insulation materials, the alternator has excellent aging resistance and breakdown resistance, ensuring long-term stable operation under high temperature and high load harsh working conditions.
In terms of environmental adaptability and safety protection, the IP23 professional dustproof and waterproof protection grade can effectively block external dust, floating debris and splashing rainwater, adapting to outdoor open-air construction sites, dusty factory workshops and humid field operation environments. The closed circulating water cooling system achieves uniform and efficient heat dissipation, thoroughly solving the overheating shutdown failure of high-power units during long-time full-load operation. The 24V DC electric starting system maintains an ultra-high startup success rate in low-temperature and harsh environments, with strong environmental tolerance. The whole unit has passed strict industrial durability and reliability tests, with low comprehensive failure rate, low operating noise and long service life, and daily maintenance is simple and labor-saving, greatly reducing later operation and maintenance costs.
3. Application Scenarios
Benefiting from 1700kW stable prime power output, 2250kVA large-capacity standby power reserve and international standard 60Hz frequency configuration, the YUCHAI YC16VTD2700-D32 diesel generator set is widely used in heavy industrial continuous power supply, overseas engineering export, key infrastructure emergency power guarantee, remote field operation and other high-demand scenarios, covering ultra-high-power power supply needs of large-scale industrial and cross-border engineering projects.
3.1 Large-Scale Heavy Industrial Production Scenarios
This 1700kW high-power diesel generator set is specially suitable for large chemical industrial parks, metallurgical smelting bases, large mining enterprises, heavy machinery manufacturing factories and other heavy industrial fields. These scenarios are characterized by high single-point power consumption, long continuous operation time and harsh working environments. The stable 1700kW prime power can fully bear 24-hour uninterrupted power supply of large production lines, heavy mechanical equipment and supporting auxiliary facilities. The strong overload resistance and transient response capability can effectively cope with instantaneous high power consumption during equipment cluster startup and peak production periods, ensuring continuous and stable industrial production and avoiding huge economic losses caused by municipal power grid failure.
3.2 Overseas Engineering & Export Project Scenarios
As a professional 60Hz dedicated diesel generator set for overseas markets, it is the preferred power supply equipment for international engineering contracting, overseas factory construction, port terminal supporting projects, offshore engineering facilities and cross-border infrastructure construction. The standard 60Hz frequency perfectly matches the local power grid standards and electrical equipment parameters of most overseas countries and regions, solving the equipment compatibility problem of domestic generators applied in overseas projects. The heavy-duty industrial body design and excellent environmental adaptability enable the unit to operate stably in complex overseas working conditions such as high temperature, low temperature, dust and high humidity, providing reliable fixed and mobile power support for field projects without municipal power grid coverage.
3.3 Core Infrastructure Emergency Standby Power Scenarios
Relying on 1800kW excellent standby power performance, the unit is widely applied as emergency standby power for key high-reliability scenarios with strict power supply requirements. It covers large data center clusters, urban core commercial complexes, Grade A hospital buildings, railway transit hubs, communication base station clusters, petrochemical safety facilities and smart industrial parks. Once the municipal power grid fails, trips, is limited or suddenly cut off, the unit can start quickly and complete automatic power switching in a short time, ensuring the continuous operation of core data systems, safety monitoring equipment, medical life support facilities and industrial control systems, and effectively preventing safety accidents, data loss and production shutdown losses caused by power outages.
3.4 Remote Field & Special Engineering Power Supply Scenarios
It is perfectly applicable to remote oil field exploitation, mountain mineral exploration, remote water conservancy hub projects, field military supporting facilities and other areas without stable municipal power grid. The unit can be used as a long-term fixed prime power supply to provide stable and reliable AC power for field operation machinery, living supporting equipment and remote monitoring systems, solving the power supply blank problem in remote and uninhabited areas and guaranteeing the smooth progress of various special field engineering projects.
4. Core Purpose
The core purpose of the YUCHAI YC16VTD2700-D32 60Hz 1700kW/2125kVA diesel generator set is to provide ultra-high-stability, large-capacity and high-reliability professional power supply guarantee for large-scale industrial production and high-standard cross-border engineering projects, covering two core usage modes: long-term main prime power supply and sudden emergency standby power supply. It is a core key equipment to ensure the continuity of industrial production and the operational safety of key infrastructure projects.
When serving as a prime power diesel generator set, this Yuchai heavy-duty ultra-high-power unit is mainly used in scenarios without stable municipal power grid coverage or insufficient grid power capacity. It undertakes 24-hour uninterrupted power supply tasks for heavy industrial production bases, overseas independent industrial parks and remote field operation projects, maintains the stable and efficient operation of the entire production and operation system, and provides lasting and reliable power source support for the normal progress of large-scale industrial and engineering projects.
When serving as an emergency standby generator set, it focuses on key fields with ultra-high power supply reliability requirements. With 1800kW strong standby power reserve, it can quickly respond to various municipal power grid faults such as sudden power failure, voltage instability, power surge and power limit. It realizes seamless power supply switching, ensures the continuous operation of precision industrial control equipment, data storage systems, public safety facilities and medical equipment, and greatly improves the anti-risk capability of enterprise production and urban public infrastructure operation.
In addition, as a high-standard 60Hz industrial generator set, it fills the market gap of ultra-high-power 60Hz power supply equipment for export engineering projects, solves the frequency and parameter matching difficulties of domestic high-power power generation equipment adapting to overseas markets, and provides standardized, stable and cost-effective high-power power supply solutions for cross-border engineering construction and international industrial investment projects.
5. FAQ (Frequently Asked Questions)
Q1: What is the actual usage difference between prime power and standby power of YC16VTD2700-D32 genset?
The 1700kW/2125kVA prime power is the long-term rated operating power of the unit, which supports 24-hour continuous stable operation and is applicable to daily long-term power supply scenarios such as remote field operation and independent heavy industrial parks. The 1800kW/2250kVA standby power is short-term peak emergency power, only designed for temporary power supply when the municipal power grid fails. It cannot operate at standby power for a long time in daily use, otherwise it will cause engine overload wear, increased fuel consumption, aggravated component aging and shortened overall service life. Users must select the operating power mode strictly according to actual application scenarios to ensure safe and stable long-term operation of the equipment.
Q2: Why is this 60Hz 2125kVA diesel generator set suitable for overseas high-power engineering projects?
This Yuchai ultra-high-power generator set adopts standard 60Hz frequency and 1800rpm rated speed, which is fully matched with the power supply standards and electrical equipment parameters of most overseas countries, completely avoiding equipment startup failure and operational abnormality caused by frequency mismatch. Equipped with IP23 dustproof and waterproof protection grade and a wide temperature adaptation range of -20℃ to 45℃, it can cope with complex overseas harsh working conditions such as high temperature, severe cold, dust and high humidity. The brushless self-excited alternator features low failure rate and simple later maintenance, which effectively reduces the operation and maintenance cost of overseas projects. Meanwhile, the YC16VTD series heavy-duty power platform has sufficient global market verification, with stable performance and high overseas user recognition, fully meeting the quality and reliability requirements of international high-power engineering projects.
Q3: How to optimize fuel consumption and extend service life for 1700kW Yuchai diesel generator set in daily operation?
The full-load fuel consumption of the YC16VTD2700-D32 unit is 444.3L/H. Scientific standardized operation and regular maintenance can effectively optimize fuel economy and prolong equipment service life. First, avoid long-term no-load or light-load operation, and control the unit load rate between 70% and 90%, which is the optimal energy-saving and stable operating range for this ultra-high-power model. Second, regularly inspect and maintain the high-pressure common rail fuel injection system, air filter, lubricating oil system and cooling system to ensure sufficient fuel combustion and stable heat dissipation, reducing invalid fuel loss and component wear. Third, configure an intelligent automatic control system to avoid frequent startup and shutdown, and conduct regular routine maintenance according to the official cycle. Standardized management can significantly reduce comprehensive operating costs and improve the overall service life of the genset.