60Hz YUCHAI YC6TH1070-D33 650kW/812.5kVA Diesel Generator Set

60Hz YUCHAI YC6TH1070-D33 650kW/812.5kVA  Diesel Generator Set

60Hz YUCHAI  650kW/812.5kVA  Diesel Generator Set

1. Technical Parameter

Parameter Category

Technical Specifications

Complete Unit Model

YUCHAI YC6TH1070-D33 Diesel Generator Set

Rated Frequency

60Hz

Prime Power

650kW / 812.5kVA

Standby Power

710kW / 887.5kVA

100% Load Fuel Consumption

184.1L/H

Rated Speed

1800rpm

Power Supply Mode

3 Phase 4 Wire

Standard Rated Voltage

440V/254V (Customizable)

Rated Power Factor

0.8 Lagging

Engine Brand & Model

YUCHAI / YC6TH1070-D33

Engine Structure

6-Cylinder, Vertical In-line, Water-cooled, Four-stroke, Turbocharged & Intercooled

Displacement

28.14L

Alternator Type

Brushless Self-excited Synchronous Alternator

Insulation Class

H Class

Protection Grade

IP23

Voltage Regulation System

Automatic AVR Voltage Regulation

Cooling System

Closed-cycle Water Cooling

Starting System

24V DC Electric Start

Applicable Emission Standard

Industrial Stage III Emission

2. Product Core Features

The YUCHAI YC6TH1070-D33 is a high-performance 650kW industrial diesel generator set developed based on Yuchai mature 6TH series heavy-duty engine platform. Tailored for global 60Hz power grid standards, this 812.5kVA Yuchai generator set balances high power output, low fuel consumption and stable operation, solving the problems of insufficient power reserve and poor environmental adaptability of traditional medium and large power generation equipment. It is widely recognized as a cost-effective industrial standby power generator for commercial and engineering scenarios.

In terms of power performance, the unit adopts a 6-cylinder turbocharged intercooled engine structure with a large displacement of 28.14L. The prime power reaches 650kW and the standby power is up to 710kW, with strong transient load carrying capacity and excellent overload resistance. When facing sudden load surges or unstable grid voltage, the unit can maintain stable power output without voltage drop or frequency offset, fully meeting the long-term continuous power demand of high-power industrial equipment. The matched brushless self-excited alternator eliminates carbon brush wear failure, greatly reducing operational failure rates compared with traditional brushed generators.

In terms of durability and safety configuration, the whole machine is equipped with H-grade high-temperature resistant insulation and IP23 professional protection grade. It can effectively resist dust invasion, rain splash and high-temperature aging, and can operate stably for a long time in high-temperature, high-humidity and dusty harsh working environments. The closed-cycle water cooling system supports continuous full-load operation under 50℃ ambient temperature, avoiding shutdown failure caused by overheating. Meanwhile, the built-in multiple protection functions of over-speed, over-voltage, low oil pressure and high water temperature realize automatic alarm and shutdown protection, effectively protecting the unit and rear-end electrical equipment.

In terms of economic operation, optimized fuel injection calibration and efficient combustion technology control the full-load fuel consumption at 184.1L/H, reaching the leading energy-saving level among similar 60Hz diesel generator sets. The integrated forged crankshaft and reinforced cylinder block structure reduce mechanical vibration and operating noise, meeting industrial environmental protection noise and emission standards. In addition, the brushless alternator design greatly reduces daily maintenance items, no frequent carbon brush replacement is required, and the later operation and maintenance cost is significantly lower than that of traditional generator sets, which is very suitable for long-term unattended operation.

In terms of adaptability, the unit is fully calibrated for 60Hz power frequency, perfectly matching the power grid standards of Southeast Asia, Africa, the Middle East and other overseas regions. With compact overall structure and standardized installation size, it supports open-type fixed installation and silent container customized installation, and can flexibly adapt to diverse on-site layout requirements of overseas engineering generator sets and domestic industrial backup power projects.

3. Main Application Scenarios

Relying on stable 60Hz power output, sufficient power reserve and strong environmental adaptability, the YUCHAI YC6TH1070-D33 heavy-duty generator set covers domestic industrial standby power and overseas engineering main power supply scenarios, and is a mainstream power supply equipment for high-power emergency power generation and off-grid power supply projects.

Heavy Industrial Production Scenarios: It is applicable to large chemical plants, mining enterprises, steel factories and industrial parks. Such scenarios have high requirements for power stability and continuous operation. The 650kW prime power can support long-term operation of large-scale production lines, fans, water pumps and mechanical equipment, and the 710kW standby power can cope with peak power consumption and sudden power failure emergencies, avoiding production shutdown and economic losses caused by grid power interruption.

Large Infrastructure Engineering: It serves as the main power supply for highway and railway construction, port terminal operation, bridge engineering and municipal key projects. Most outdoor engineering sites have no stable grid coverage. This 887.5kVA standby diesel generator can provide continuous and stable power support for construction machinery, on-site office, temporary living power and engineering debugging, adapting to complex outdoor construction environments.

Public Facilities & Emergency Support: It is widely used as emergency standby power for large shopping malls, commercial buildings, hospital wards, data center computer rooms and civil air defense projects. For key equipment that cannot be powered off, the unit’s fast start-up response and stable voltage output can ensure the normal operation of precision instruments, emergency lighting and fire-fighting equipment, and is a professional fire emergency backup generator for public buildings.

Overseas Export & Remote Off-grid Areas: As a dedicated 60Hz export diesel generator set, it fully conforms to overseas power grid frequency and voltage standards. It is widely used in overseas infrastructure construction, remote mountainous areas, island power supply and rural power grid renovation projects, solving the power shortage problem of off-grid areas with no grid coverage.

4. Core Product Uses

The YUCHAI YC6TH1070-D33 650kW/812.5kVA diesel generator set has clear core positioning, mainly covering emergency standby power guarantee, long-term off-grid main power supply, peak power regulation and temporary engineering power support, meeting the diversified power demand of medium and high-power industrial and commercial scenarios.

Emergency Standby Power Supply: This is the most widely used core function of the unit. When the municipal grid fails, power is cut off or voltage fluctuates abnormally, the unit can start quickly and switch power supply automatically, ensuring uninterrupted operation of key production equipment and public service facilities. It is an essential power guarantee equipment for industrial enterprises and key public infrastructure.

Long-term Off-grid Main Power Generation: In remote mines, field operation bases, overseas unpowered areas and other scenarios without grid coverage, the unit can be used as the main power supply equipment for 24-hour continuous power generation. With stable power performance and low failure rate, it can fully meet the daily production, operation and living power demand of off-grid sites.

Industrial Peak Power Compensation: For large factories and industrial parks with large peak-valley power difference, the unit can be started during grid power peak hours to supplement power supply, effectively relieve grid power supply pressure, avoid power limitation and peak power failure, and ensure the continuous and stable operation of enterprise production lines.

Temporary Engineering Power Support: The unit features flexible installation and strong mobility, which can provide stable temporary power for short-term engineering construction, equipment debugging, field rescue and emergency disaster relief projects, and is a reliable mobile power guarantee for various temporary operation scenarios.

5. Frequently Asked Questions (FAQ)

Q1: What is the actual usage difference between prime power and standby power of YC6TH1070-D33 generator set?

The 650kW prime power is the long-term sustainable operating power of the unit, supporting 24-hour continuous full-load operation, which is suitable for off-grid main power supply and daily long-term power generation scenarios. The 710kW standby power is emergency overload power, only used for short-time power compensation when grid power fails. It cannot run at full load for a long time, and the cumulative overload operating time shall not exceed 10% of the total working hours. Users must distinguish the usage scenarios to avoid engine wear and service life reduction caused by long-term standby power operation.

Q2: Is this 60Hz Yuchai generator set suitable for overseas export and high-temperature area operation?

This unit is specially calibrated for 60Hz frequency, which is fully compatible with the power grid standards of most countries in Southeast Asia, Africa, South America and the Middle East. Equipped with IP23 protection grade and H-grade high-temperature resistant insulation, it can resist high temperature, humidity and dust erosion. The matched high-efficiency water cooling system ensures stable power output under 50℃ high-temperature environment. With Yuchai’s global after-sales service system, it has become the preferred high-power export generator set for overseas engineering projects.

Q3: What are the key daily maintenance points for YC6TH1070-D33 diesel generator set?

This brushless generator set has low maintenance difficulty and cost. Daily maintenance mainly includes four key points: first, regularly check diesel fuel, lubricating oil and cooling water level to ensure sufficient medium supply; second, clean radiator and alternator dust regularly to avoid poor heat dissipation and high-temperature failure; third, inspect starting battery and circuit connection to guarantee reliable start-up performance; fourth, replace filter elements and lubricating oil regularly according to operating hours. The brushless structure avoids carbon brush replacement work, greatly reducing daily maintenance workload and equipment failure rate.

 


Quick Inquiry